Compressor building design
dynamics
Pump Skid Natural Frequency
For one fire pump skid, motor and pump are running at 1800rpm, the rotor first mode natural frequency is about 2400rpm (40Hz). Solid Structural Design designed the skid so that the skid first mode natural frequency is about 0.1Hz. The skid natural frequency is more than 20% away from the machine operating speed and pump critical speed.
Structural Dynamic Analysis Model
For Suncor 4000HP Pump House. Mode 1 Structural Dynamic Analysis Model.