Compressor building design
Skid
Pump Skid Natural Frequency
For one fire pump skid, motor and pump are running at 1800rpm, the rotor first mode natural frequency is about 2400rpm (40Hz). Solid Structural Design designed the skid so that the skid first mode natural frequency is about 0.1Hz. The skid natural frequency is more than 20% away from the machine operating speed and pump critical speed.
Solid’s low-cost engineering and manufacturing center in China
Solid Structural is glad to showcase our low cost engineering and manufacturing center (LEMC) in China. Team with 5 large steel shops in China, we can meet all clients need from different industries: government, transportation, mining, power & energy, oil & gas, agriculture, offshore, shipbuilding, and port machinery. We help you realize your ideas at low cost. From engineering, design, shop detailing, manufacturing, and transportation, our management team can handle your projects with confidence. Our engineers use American, Canadian, British, and Australian codes. The shops are under ISO 9001 quality system.
Structural Dynamic Analysis Model
For Suncor 4000HP Pump House. Mode 1 Structural Dynamic Analysis Model.
Skid Finite Element Analysis Model
The pump skid is connected to a building skid. FEA model was built to study the stress in the skid. The results show that the stiffener plate needed to be added and re-arranged.